NIST TN 1863-1 4-Story SMF Benchmark Study

A performance-based engineering tutorial modeling the NIST TN 1863-1 4-story building as a pure 3D Special Moment Frame in both principal directions, with ASCE 41 RBS beam hinges and coupled P-M-M column hinges, analyzed for modal response and the bidirectional Northridge BSE-1 record.

Time
About 35 minutes
Level
Advanced
You'll need
Performance-Based Seismic Assessment
You're done when
A pure 3D SMF model with modal and bidirectional BSE-1 time-history results
On this page
  1. 1. Archetype Overview & Benchmark Purpose
  2. 2. NIST Report Reference & Building Geometry
  3. 3. Core Modeling Assumptions: Transition to Pure SMF
  4. 4. Member Schedules, Section Properties & RBS Geometry
  5. 5. Nonlinear Constitutive Modeling in VFO Pro
  6. 6. Step-by-Step VFO Pro Modeling Workflow
  7. 7. Simulation Results
  8. 8. Analysis Settings Used for BSE-1

Model Files

The study package for inspecting, modifying, and running the NIST 4-story pure SMF model contains the files below.

Package Contents:

  • NIST_4Story_SMF_3D.vfodb — the 384-element VFO Pro model file with ASCE 41 RBS beam hinges and coupled P-M-M column hinges.
  • Northridge_CanyonCountry_LOS270.txt & LOS000.txt — the ground-motion acceleration records (in units of g, 0.01 s time step).

Download Model Files

1. Archetype Overview & Benchmark Purpose

This benchmark study provides a complete modeling, configuration, and analysis walkthrough for the NIST Technical Note 1863-1 4-Story Special Moment Frame (SMF) archetype in VFO Pro. The building is modeled as a full 3D Pure Special Moment Frame structure in both orthogonal building directions (XX and YY), capturing concentrated beam plasticity, multi-axial column interaction, and second-order P−ΔP-\Delta geometric effects.

National Institute of Standards and Technology (NIST) Technical Note 1863-1 evaluates first-generation performance-based seismic design procedures (ASCE/SEI 41-06 and ASCE/SEI 41-13) against standard archetype steel buildings designed in accordance with ASCE/SEI 7-10. This 4-story archetype represents a typical commercial office building situated in a high-seismicity region in Los Angeles, California.

Reference PublicationAssessment of First Generation Performance-Based Seismic Design Methods for New Steel Buildings, Volume 1: Special Moment Frames (NIST TN 1863-1, Feb 2015)
Authors & DOIJohn L. Harris III and Matthew S. Speicher · doi:10.6028/NIST.TN.1863-1
Building Archetype4-Story Steel Office Building, Risk Category II (Ie=1.0I_e = 1.0), Seismic Design Category Dmax⁡D_{\max} (Los Angeles, CA)
Footprint & Height150 ft×100 ft150\text{ ft} \times 100\text{ ft} (15,000 ft215{,}000\text{ ft}^2 per floor), Total Height H=60 ftH = 60\text{ ft} (h1=18 fth_1 = 18\text{ ft}, h2−4=14 fth_{2-4} = 14\text{ ft})
Framing System3D Pure Special Moment Frame (SMF): 3 bays in XX (Grids 1 & 6), 3 bays in YY (Grids A & F), gravity framing elsewhere
Material SpecificationASTM A992 Grade 50 Steel (Fy=50 ksiF_y = 50\text{ ksi}, Expected Fye=55 ksiF_{ye} = 55\text{ ksi}, E=29,000 ksiE = 29{,}000\text{ ksi})
Seismic DemandBSE-1 (10%/50 yr10\%/50\text{ yr}, SDS=1.0g,SD1=0.6gS_{DS} = 1.0g, S_{D1} = 0.6g), represented by the Northridge Canyon Country record pair scaled by 1.396
Reported Analyses6-mode eigenvalue analysis, nonlinear gravity (Dead + 0.25 Live), bidirectional nonlinear dynamic time history at BSE-1

2. NIST Report Reference & Building Geometry

The archetype layout reflects modern California commercial steel framing with composite metal deck floor diaphragms. In NIST TN 1863-1 Section 2.1, two standard design variations are presented: an Equivalent Lateral Force (ELF) design and a Response Spectrum Analysis (RSA) design. This study implements the ELF member schedule.

NIST Figure 2-4 Typical Floor Framing Plan Click to zoom
Figure 2-1: NIST TN 1863-1 Figure 2-4 — Typical Floor Framing Plan showing 150 ft × 100 ft building footprint and framing grid lines.

The building footprint spans 150 ft along the longitudinal (XX) axis across 5 equal 30 ft bays (Grids A through F), and 100 ft along the transverse (YY) axis across 5 equal 20 ft bays (Grids 1 through 6). Floor elevations are established at 18 ft (Level 2), 32 ft (Level 3), 46 ft (Level 4), and 60 ft (Roof).

NIST Figure 2-11 4-Story SMF Elevation and Member Sizes Click to zoom
Figure 2-2: NIST TN 1863-1 Figure 2-11 — 4-Story SMF Elevation, member schedules, and Reduced Beam Section (RBS) geometry.

In the longitudinal (XX) direction, lateral resistance is provided by two identical 3-bay perimeter moment frames on Grid Lines 1 and 6, spanning between Grids B, C, D, and E (90 ft frame length). Column sections step down at the 3rd floor (elevation 32 ft). Beam connections feature Reduced Beam Sections (RBS) designed per AISC 358-10 to force flexural plastic hinging away from the column face.

3. Core Modeling Assumptions: Transition to Pure SMF

An essential structural distinction in this study is the transition from the original mixed SFRS to a Pure Special Moment Frame system in both principal directions.

The Original NIST Dual Configuration

In the original NIST TN 1863-1 building design, the longitudinal direction (XX) was designed as an SMF, while the transverse direction (YY) was designed as a single-bay Special Concentrically Braced Frame (SCBF) located between Grids 2 and 3 on Grids A and F.

NIST Figure 2-15 Original Transverse SCBF Elevation Click to zoom
Figure 3-1: NIST TN 1863-1 Figure 2-15 — Original single-bay chevron SCBF elevation along the transverse direction.

Engineering Rationale for the Pure SMF Configuration

When conducting advanced nonlinear dynamic response history analysis (NDRHA) under severe bidirectional seismic records (e.g. maximum considered earthquake shaking), the single-bay chevron braced frame introduces significant modeling challenges:

  • Severe Axial Force Concentration: With only a single 20 ft bay resisting all transverse lateral shear, brace axial forces reach extreme levels, generating large overturning tensile uplifts and compressive loads in the adjacent columns.
  • Brace Buckling & Fracture Sensitivity: Under traditional phenomenological brace formulations, cyclic buckling and tension rupture create sudden stiffness drops that induce numerical convergence stalls during intense ground motion peaks.
  • Pure Moment Frame Benchmark: Replicating the 3-bay moment frame architecture on Grids A and F (spanning Bays 2–5) creates an ideal, purely ductile dual-axis benchmark building. This allows structural engineers to rigorously study 3D multi-axial column yielding (P−My−MzP-M_y-M_z) and beam plastic hinge behavior under bidirectional excitation without brace fracture anomalies.
Transverse Frame Geometry & Column Orientation

The transverse SMFs on Grids A and F span three 20 ft bays between Grids 2, 3, 4, and 5 (total frame length = 60 ft). The columns in these transverse frames are rotated with localAxes = 90, ensuring that their strong flexural axis (IyI_y in VFO Pro) is aligned directly with the global YY seismic demands.

           Grid A        Grid B        Grid C        Grid D        Grid E        Grid F
Grid 6  O=============+=============+=============+=============+=============O  (100')
(North) |             |  [======== 3-Bay SMF Frame 1 (X) =======] |             |
        |             |                                         |             |
Grid 5  #=============+-------------+-------------+-------------+-------------#  (80')
        |   3-Bay     |                                         |   3-Bay     |
Grid 4  #  SMF (Y)    |                                         |  SMF (Y)    #  (60')
        |  Frame 3    |                                         |  Frame 4    |
Grid 3  #  (West)     |                                         |  (East)     #  (40')
        |             |                                         |             |
Grid 2  #=============+-------------+-------------+-------------+-------------#  (20')
        |             |                                         |             |
Grid 1  O=============+=============+=============+=============+=============O  (0')
(South) |             |  [======== 3-Bay SMF Frame 2 (X) =======] |             |
        0'           30'           60'           90'          120'          150' (X)

Legend:
  [====]  Special Moment Frame (SMF) with RBS Beams & Fixed/Coupled PMM Columns
  [----]  Gravity Framing with Pinned Beam Connections (m3 released)
  O       Corner Gravity Columns (W14x90, Base Pinned)
  #       SMF Y-Columns (W14x257/233 int, W14x159/145 ext, localAxes = 90, Base Fixed In-Plane)
  +       Interior Gravity Columns (W14x90, Base Pinned)

4. Member Schedules, Section Properties & RBS Geometry

The structural members are modeled from standard AISC Wide-Flange cross sections using ASTM A992 Grade 50 steel with expected yield strength Fye=55 ksiF_{ye} = 55\text{ ksi} (Ry=1.1R_y = 1.1) per ASCE 41-13 Table 9-1.

4.1 Beam Schedule & Reduced Beam Section (RBS) Parameters

Beam sections vary across the height to match the ASCE 7-10 Equivalent Lateral Force design:

Story LevelElevationBeam SectionCut aa (in)Length bb (in)Depth cc (in)ZRBS/ZxZ_{RBS} / Z_x
Roof60’-0” (720”)W24×553.7516.01.750.741
4th Floor46’-0” (552”)W24×764.5016.02.250.741
3rd Floor32’-0” (384”)W24×844.7516.02.250.763
2nd Floor18’-0” (216”)W24×844.7516.02.250.763

4.2 Column Schedules

SMF column sections change at the 3rd floor level (elevation 32 ft): the lower two stories use the heavier shapes. Splice details are not modeled.

LocationStories 1 & 2 (Elev 0’–32’)Stories 3 & 4 (Elev 32’–60’)Base Boundary ConditionColumn Local Axis
SMF Interior ColumnsW14×257W14×233Fixed in-plane (ux, uy, uz and in-plane rotation)Lines 1 & 6: 0° · Grids A & F: 90°
SMF Exterior ColumnsW14×159W14×145Fixed in-plane (ux, uy, uz and in-plane rotation)Lines 1 & 6: 0° · Grids A & F: 90°
Gravity Columns (corner & interior, 20 total)W14×90W14×90Pinned (ux, uy, uz = 1)0°

4.3 Gravity Members & Moment Releases

The building contains 192 gravity beam elements (96 along XX and 96 along YY). All XX-direction gravity beams are W16x26; along YY, 80 are W27x84 girders and 16 are W16x26. All gravity beams have major-axis moment releases assigned at both ends (releases: { i: { m3: true }, j: { m3: true } }), accurately representing standard shear-tab web connections and ensuring zero unintended moment transfer into gravity columns.

5. Nonlinear Constitutive Modeling in VFO Pro

VFO Pro implements concentrated plasticity for both frame beams and columns, providing numerically stable performance-based assessments conforming to ASCE 41-13.

5.1 Beam Moment-Rotation Plastic Hinges

Beam elements are modeled using OpenSees concentrated plasticity via beamIntegration('ConcentratedPlasticity'). Each RBS hinge is defined by a yield moment MyeM_{ye} and five backbone points given as scale factors of MyeM_{ye}. MyeM_{ye} is the expected plastic moment at the center of the reduced beam section, Mye=FyeZeM_{ye} = F_{ye} Z_e with Fye=55 ksiF_{ye} = 55\text{ ksi} and Ze=Zx−2 cRBS tf (d−tf)Z_e = Z_x - 2\,c_{\text{RBS}}\,t_f\,(d - t_f), where cRBSc_{\text{RBS}} is the RBS cut depth (NIST TN 1863-1, Appendix C gives Ze=143.2 in3Z_e = 143.2\text{ in}^3 and Mpe=7,876 kip-inM_{pe} = 7{,}876\text{ kip-in} for the W24×84). The rotation parameters follow ASCE 41: a=0.05−0.0003 da = 0.05 - 0.0003\,d (0.0428 rad for d=24.1 ind = 24.1\text{ in}, as in Appendix C), b=1.2ab = 1.2a and a residual strength ratio c=0.5c = 0.5.

PointMomentRotation (rad)
1 (yield)0.66 Mye0.66\,M_{ye}0.001
20.95 Mye0.95\,M_{ye}0.25a0.25a
31.00 Mye1.00\,M_{ye}aa
4c Myec\,M_{ye}a+0.8(b−a)a + 0.8(b - a)
5c Myec\,M_{ye}bb
HingeZxZ_x (in³)cRBSc_{\text{RBS}} (in)ZeZ_e (in³)MyeM_{ye} (kip-in)aa (rad)bb (rad)
mhW24x84_rbs2242.25143.27,8740.04280.0513
mhW24x76_rbs2002.25129.07,0920.04280.0514
mhW24x55_rbs1341.7593.25,1250.04290.0515

The limit states (IO, LS, CP) are set to 0.25a0.25a, 0.9a0.9a and aa.

Initial Hinge Stiffness

The first backbone point sits at 0.001 rad, so the hinge has a finite initial rotational stiffness (≈5.2×106 kip-in/rad\approx 5.2\times10^{6}\text{ kip-in/rad} for the W24×84, several times the beam's own end rotational stiffness 6EI/L≈1.1×106 kip-in/rad6EI/L \approx 1.1\times10^{6}\text{ kip-in/rad}). Between points 1 and 2 the backbone keeps a post-yield stiffness of about 2×105 kip-in/rad2\times10^{5}\text{ kip-in/rad} (about 4% of the initial stiffness). The residual branch (points 4–5) is flat.

5.2 Column Coupled P-M-M Hinges (ASDCoupledHinge3D)

SMF columns undergo concurrent axial force and bidirectional bending demands. In VFO Pro, column hinges are implemented using the ASDCoupledHinge3D component via Frame Compound Components (zeroLengthSection elements) at the top and bottom of each column lift:

  • Fully models 3D yield surface interaction across axial force (PP) and biaxial moments (My,MzM_y, M_z) per AISC 360-16.
  • Captures softening, cyclic degradation, and axial shortening under high axial compression.
  • Backbone: after yielding, the strength hardens to 1.05 times the yield strength (a hardening ratio of 1.05) at the plastic rotation a=0.02 rada = 0.02\text{ rad}, and then softens toward the residual strength (c=0.2c = 0.2) at b=0.06 radb = 0.06\text{ rad}. The limit states are 0.01, 0.02 and 0.03 rad.
  • Initial Flexural Stiffness Calibration: In zero-length compound hinges, an excessively stiff elastic rotational penalty (Kflex>1011 kip-in/radK_{\text{flex}} > 10^{11}\text{ kip-in/rad}) creates severe matrix ill-conditioning. VFO Pro calibrates the yield rotation floor to θy,min⁡=10−3 rad\theta_{y,\min} = 10^{-3}\text{ rad} (Kflex∼107 kip-in/radK_{\text{flex}} \sim 10^7\text{ kip-in/rad}), eliminating ill-conditioning while preserving true elastic drift and yield thresholds.

6. Step-by-Step VFO Pro Modeling Workflow

The following step-by-step procedure walks through building and analyzing the 3D pure SMF model in the VFO Pro graphical interface:

  1. Project Setup, Grid System & Story Elevations

    Set project units to kip-in-sec (F=kip,L=in,T=secF = \text{kip}, L = \text{in}, T = \text{sec}). Under Grids, define Cartesian lines: X=[0,360,720,1080,1440,1800] inX = [0, 360, 720, 1080, 1440, 1800]\text{ in} and Y=[0,240,480,720,960,1200] inY = [0, 240, 480, 720, 960, 1200]\text{ in}. Under Stories, define Base (0 in0\text{ in}), L02 (216 in216\text{ in}), L03 (384 in384\text{ in}), L04 (552 in552\text{ in}), and Roof (720 in720\text{ in}).

  2. Materials & AISC Sections

    Under Define › Materials, create A992_Grade50 with E=29,000 ksiE = 29{,}000\text{ ksi}, Fy=50 ksiF_y = 50\text{ ksi}, and Fye=55 ksiF_{ye} = 55\text{ ksi}. Under Sections, import the required shapes: columns (W14x257, W14x233, W14x159, W14x145, W14x90) and beams (W24x84, W24x76, W24x55, W27x84, W16x26).

  3. Define Nonlinear Hinge Properties

    Under Define › Frame Hinges, configure the moment-rotation hinges for beams and coupled P-M-M hinges for columns:

    Defining ASCE 41 Moment-Rotation Beam Hinge mhW24x84_rbs in VFO Pro Click to zoom
    Figure 6-1: Defining the ASCE 41 moment-rotation beam hinge mhW24x84_rbs: yield moment Mye=7,873.9 kip-inM_{ye} = 7{,}873.9\text{ kip-in}, moment scale factors (0.66, 0.95, 1, 0.5, 0.5) and the rotations of points 2–5.
  4. Assign Compound Component Column Hinges & Beam Integration

    Select the SMF columns and open Assign › Frame › Hinges. Select Frame Compound Component and assign ASDCoupledHinge3D (e.g. pmmCol_W14x257) at column ends. For SMF beams, select Beam Integration and assign concentrated-plasticity-beam-integration with the respective RBS hinge.

    Assigning Frame Compound Component Column Hinges in VFO Pro Click to zoom
    Figure 6-2: Assigning multi-axial coupled column hinges (pmmCol_W14x257) and section integration properties in VFO Pro.
  5. Assign Gravity Loads & Visual Confirmation

    Assign distributed line loads to the floor beams under the Dead load pattern (self-weight is included in the pattern). Use Display › Display Loads to confirm the assigned loads in the viewport.

    Frame Load Assignment and Visual Confirmation on 4-Story SMF in VFO Pro Click to zoom
    Figure 6-3: Display Loads view of the Dead frame line loads on all four floors in VFO Pro. The labels show wzw_z between −0.25-0.25 and −1.22 klf-1.22\text{ klf}, depending on tributary width.
  6. Boundary Conditions, Diaphragms & Lumped Masses

    Restrain the 16 SMF column bases (Grids B–E on Lines 1 & 6; Lines 2–5 on Grids A & F) against translation (ux, uy, uz = 1) and against rotation in the plane of their frame (ry = 1 for the columns of the frames along XX, rx = 1 for the columns of the frames along YY). This follows NIST TN 1863-1, where the column bases of the lateral system are rotationally restrained in the plane of the frame and unrestrained out of plane. Assign translational pins (ux, uy, uz = 1, rx, ry, rz = 0) to the 20 gravity column bases. Apply rigid floor diaphragms (autoFloorDiaphragm) and the floor seismic masses as nodal masses (NIST TN 1863-1 seismic weights: Roof 1,095 kips, 4th floor 1,345 kips, 3rd floor 1,359 kips, 2nd floor 1,377 kips; 5,176 kips in total).

    Complete 3D Structural View of 4-Story Pure SMF in VFO Pro Click to zoom
    Figure 6-4: Complete 3D model view of the 4-story pure SMF showing column base supports, diaphragm master nodes, and perimeter moment frames.
  7. Configure Analysis Load Cases

    Under Define › Loads › Cases, define the cases used in this study:

    • Modal: 6 modes using the genBandArpack eigenvalue solver.
    • Dead: Nonlinear static gravity case (20 load steps) combining the Dead pattern with 0.25 of the Live pattern.
    • Northridge_BSE1: Bidirectional nonlinear dynamic time-history case starting from Dead (Δt=0.01 s\Delta t = 0.01\text{ s}, 2000 steps, Rayleigh damping of 2.5% at modes 1 and 2). Acceleration data: LOS270 along XX and LOS000 along YY, each with scale factor 1.396.

    The model file also contains Pushover_X, Pushover_Y and Northridge_BSE2 cases. They are not part of this study.

    Time-History Load Case Definition Northridge_BSE1 in VFO Pro Click to zoom
    Figure 6-5: VFO Pro Load Case Definition for Northridge_BSE1 nonlinear dynamic time-history analysis with 2,000 output steps at Δt=0.01 s\Delta t = 0.01\text{ s}.

7. Simulation Results

This study reports the modal response and the bidirectional Northridge_BSE1 time-history response of the pure SMF model.

7.1 Modal Periods, Frequencies & Mode Shapes

The eigenvalue analysis returns the first six modes of the 3D model:

ModePeriod TT (s)Frequency ff (Hz)Dominant DirectionEffective Modal Mass (%)Description
Mode 11.7090.585Longitudinal (XX)87.81st translational mode in XX
Mode 21.5680.638Transverse (YY)89.11st translational mode in YY
Mode 31.1020.908Torsion (θz\theta_z)—1st torsional mode
Mode 40.4892.044Longitudinal (XX)9.72nd translational mode in XX
Mode 50.4742.108Transverse (YY)8.62nd translational mode in YY
Mode 60.3412.929Torsion (θz\theta_z)—2nd torsional mode
Mode Shape 1 3D Rendering in VFO Pro Click to zoom
Figure 7-1: Mode 1 rendering with color contours in VFO Pro Post-Processing (T1=1.71 sT_1 = 1.71\text{ s}, dominant in the XX direction).
Mode Shape 2 3D Rendering in VFO Pro Click to zoom
Figure 7-2: Mode 2 rendering in VFO Pro Post-Processing (T2=1.57 sT_2 = 1.57\text{ s}, dominant in the YY direction).

Modes 1 and 2 are clean translational modes in XX and YY, carrying about 88% and 89% of the effective modal mass. The first torsional mode (T3=1.102 sT_3 = 1.102\text{ s}) has a period about 64% of the fundamental period, so it is well separated from the two translational modes.

7.2 Nonlinear Dynamic Time-History Response (BSE-1)

The model was subjected to bidirectional excitation from the 1994 Northridge, Canyon Country – WLC station record pair (FEMA P-695 record set, NIST TN 1863-1 Table A-1). Component LOS270 acts along XX and LOS000 along YY, each scaled by 1.396 for the BSE-1 hazard level. Each record has 1,999 points at 0.01 s (about 20 s), and the analysis starts from the gravity state of the Dead case.

StoryElevation (in)Peak IDR XX (%)Peak IDR YY (%)Residual IDR XX (%)Residual IDR YY (%)
Story 4 (Roof)552 to 7201.281.980.040.56
Story 3384 to 5521.361.990.020.59
Story 2216 to 3841.482.070.080.66
Story 10 to 2161.371.880.070.71

Interstory drift ratios (IDR) are computed from the displacements of the IDR node stack defined in the model. Residual values are taken at the end of the record (t=19.99 st = 19.99\text{ s}). Drift is spread fairly evenly over the height, with story peaks of 1.28–1.48% in XX and 1.88–2.07% in YY. The largest values are 1.48% in XX (story 2, at t=10.59 st = 10.59\text{ s}) and 2.07% in YY (story 2, at t=6.52 st = 6.52\text{ s}). Residual drift is below 0.1% in XX and 0.56–0.71% in YY. The XX and YY peaks occur at different times because the two ground-motion components peak at different moments.

All 96 beam hinge ends yield, and 51 exceed the IO limit (0.25a=0.01070.25a = 0.0107 rad). Only one end exceeds the LS and CP limits: element 351 (W24×76, 4th floor, Grid F), end I, reaches 0.067 rad at t=10.68 st = 10.68\text{ s}, beyond the end of its backbone (b=0.0513b = 0.0513 rad). At that instant the two column hinges at the same joint also rotate by about 0.08 rad within about 0.05 s. The next largest beam hinge rotation is 0.0238 rad (element 356, end I). Among the column hinges, 15 of 128 exceed 0.01 rad. Figure 7-3 shows the most demanding second-floor beam hinge, element 267 end J, which peaks at 0.0168 rad (t=6.44 st = 6.44\text{ s}), between the IO and LS limits.

Frame Hinge Hysteresis Loop and 3D Plastic State in VFO Pro Click to zoom
Figure 7-3: Frame Hinge Post-Processing — moment-rotation (M−θM-\theta) hysteresis curve for beam element 267, end J (mhW24x84_rbs) under Northridge_BSE1, plotted against the ASCE 41 limit states (IO, LS, CP). The marker is at t=6.44 st = 6.44\text{ s} (M=7,556 kip-inM = 7{,}556\text{ kip-in}, θ=0.0168 rad\theta = 0.0168\text{ rad}, between IO and LS); the 3D view shows the deformed frame with hinge states at that step.
Reporting Panel showing Story IDR Stack in VFO Pro Click to zoom
Figure 7-4: VFO Pro Reporting Panel — interstory drift ratio (IDR X and IDR Y) stack chart plotted across building elevations (Base, L02, L03, L04, Roof) under Northridge_BSE1. Each curve is the drift profile at the instant of the largest drift in that direction (XX at t=10.59 st = 10.59\text{ s}, YY at t=6.52 st = 6.52\text{ s}).

8. Analysis Settings Used for BSE-1

The Northridge_BSE1 case uses the following settings, all visible in the case form under Define › Loads › Cases:

8.1 Damping

Rayleigh damping of 2.5% of critical is specified at modes 1 and 2. The mass- and stiffness-proportional coefficients are computed from the periods of those two modes at the start of the case.

8.2 Integration & Solution Parameters

SettingValue
Initial conditionDead (gravity state)
Time step / output stepsΔt=0.01 s\Delta t = 0.01\text{ s} / 2000
IntegratorNewmark, average acceleration (γ=0.5\gamma = 0.5, β=0.25\beta = 0.25)
AlgorithmModified Newton
Convergence testEnergy increment, tolerance 10−410^{-4}, up to 1000 iterations
Equation solver / numbererUmfPack / RCM
Constraint handlerTransformation (rigid floor diaphragms)
Geometric nonlinearityP−ΔP-\Delta on all columns

Last updated November 12, 2026 · applies to vfopro 20261107.0.0 or later